Address Configuration for Connected Devices
386 AlterPath OnBoard Administrator’s Guide
• When configuring “connSub1” for access to sub1: Left subnet:
192.168.1.0/24
• When configuring “connSub2” for access to sub2: Left subnet:
192.168.4.0/22
• Right ID: @workstation
• Right IP address: the IP address of the user’s workstation: 12.34.56.78
• Right nexthop: leave blank if the user’s workstation and the OnBoard
are able to exchange packets.
• Right subnet: leave blank
The other IPSec configuration parameters (such as Authentication protocol
and Boot action) would be determined by the site’s policy, equipment
compatibility, and site routing requirements.
Note: In some circumstances (for example, if packets are being blocked by a
firewall on the client’s default gateway), the user’s workstation and the
OnBoard are not going to be able to exchange packets. Setting one or both of
the Right and Left nexthop parameters to the IP address of a host route and
selecting “Add and route” as the boot action may be needed to create a route
that allows the two endpoints to communicate.
The following screen example shows the configuration on the Web Manager
Network → VPN connections: IPSec Add new connection dialog for a
connection named “connSub1,” with the values specified from the above list.
Configuration of “connSub2” would be similar, with a different “Connection
name” and “Left subnet values.”