Configuration>Network>Host Settings
302
AlterPath OnSite Administrators and Users Guide
a. Enter the name assigned to the IP address of the OnSite in the “Host
Name” field.
b. Enter or change the console banner in the “Console Banner” field.
The console banner appears on the console when the user logs into
and exits from a port as a way to verify or identify the particular port
connection
c. Enter the IP address of the OnSite in the “Primary IP” field.
d. Enter the netmask in the “Network Mask” field.
e. Enter an optional secondary IP address in the “Secondary IP” field.
f. Specify the netmask of the secondary IP in the “Secondary Network
Mask” field.
g. Specify the desired maximum transmission unit in the “Maximum
Transmission Unit” field.
4. Under “DNS Service” specify or change the following information, if
desired.
a. Enter the address of the domain name server in the “Primary DNS
Server” field.
b. If there is a backup DNS server, enter the address of the secondary
DNS in the “Primary DNS Server” field
c. Enter the domain in the “Domain Name” field.
d. Enter the IP address of the gateway in the “Gateway IP” field.
5. To enable Ethernet failover (bonding), do the following steps.
a. Click the “Enabled” checkbox under “Bonding.”
“Miimon” and “Updelay” fields appear.
b. If desired, change the value in the “miimon” field.
The default is 100.
c. If desired, change the value in the “Updelay” field.
The default is 200.
6. Click “apply changes.”