Cyclades AlterPath OnBoard Guide de l'utilisateur Page 319

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 688
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 318
Web Manager for OnSite Administrators 271
Configuration>Serial/AUX>Notifications
3. Select “Email,” “Pager,” or “SNMP trap” from the pull-down menu.
4. To create a new entry for an event to trigger an alarm or notification, click
the Add button.
5. To edit a previously-configured trigger, click the Edit button.
6. Go to one of the following procedures.
•“"To Configure a Trigger for Email Notification for Serial
Ports [Expert]
“To Configure a Trigger for Pager Notification for Serial
Ports [Expert]” on page 272
“To Configure a Trigger for SNMP Trap Notification for Serial
Ports Expert]” on page 272
T To Configure a Trigger for Email Notification
for Serial Ports [Expert]
1. Go to Configuration>Serial/AUX>Notifications in Expert mode, select
“Email” from the pull-down menu; optionally, configure an alarm to
sound when the trigger action occurs; and click either Add or Edit.
If needed, see “To Choose a Method for Sending Notifications for Serial
Port Data Buffering [Expert]” on page 217.
2. Specify the function you want to trigger a notification in the “Alarm
Trigger” field using the required syntax.
3. Enter the recipient for notification email in the “To” field.
Enter the username only in this field. The email is sent to
username@server, where server is the value entered in Step 7.
4. Enter an email address identifying the OnSite in the “From” field.
5. Enter the subject in the “Subject” field.
6. Enter an explanatory text message in the “Body” field.
7. Enter the SMTP servers IP address or DNS name in the “SMTP Server”
field.
8. Enter the SMTP port number in the “SMTP Port” field.
Vue de la page 318
1 2 ... 314 315 316 317 318 319 320 321 322 323 324 ... 687 688

Commentaires sur ces manuels

Pas de commentaire